{"id":209,"date":"2023-07-24T22:45:15","date_gmt":"2023-07-24T20:45:15","guid":{"rendered":"http:\/\/www.wilpo.pl\/?page_id=209"},"modified":"2024-01-23T13:44:07","modified_gmt":"2024-01-23T12:44:07","slug":"gestosciomierz-radiometryczny-wilpo-cg-111","status":"publish","type":"page","link":"https:\/\/www.wilpo.pl\/en\/radiometric-density-meter-wilpo-cg-111\/","title":{"rendered":"Isotope Density Meter WILPO CG 111"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; module_class=&#8221;sekcja-produkt&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; use_background_color_gradient=&#8221;on&#8221; background_color_gradient_stops=&#8221;rgba(255,255,255,0.91) 0%|rgba(255,255,255,0.72) 100%&#8221; background_color_gradient_overlays_image=&#8221;on&#8221; background_image=&#8221;https:\/\/www.wilpo.pl\/wp-content\/uploads\/2023\/07\/Projekt-bez-nazwy-22.jpg&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;|700|||||||&#8221; text_text_color=&#8221;#000000&#8243; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h1>G\u0119sto\u015bciomierz radiometryczny WILPO CG 111<\/h1>\n<h2>Przeznaczenie \u2013 zastosowanie<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p><span>Izotopowy G\u0119sto\u015bciomierz WILPO CG 111 przeznaczony jest do ci\u0105g\u0142ych pomiar\u00f3w g\u0119sto\u015bci cieczy lub zawiesin transportowanych w ruroci\u0105gach a szczeg\u00f3lnie w zawiesin popio\u0142u.<\/span><\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Budowa<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p><span>G\u0119sto\u015bciomierz CG 111 jest urz\u0105dzeniem bezobs\u0142ugowym, zabudowywanym bezpo\u015brednio na ruroci\u0105gach transportuj\u0105cych zawiesiny. Uk\u0142ad pomiarowy sk\u0142ada si\u0119 z kontrolera, kt\u00f3ry mo\u017ce pracowa\u0107 samodzielnie lub wsp\u00f3\u0142pracowa\u0107 z zewn\u0119trzn\u0105 jednostka PC oraz z modu\u0142u zawieraj\u0105cego \u017ar\u00f3d\u0142o izotopowe i z modu\u0142u detekcyjnego.<\/span><\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.wilpo.pl\/wp-content\/uploads\/2023\/07\/GC111.jpg&#8221; title_text=&#8221;GC111&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; text_font_size=&#8221;12px&#8221; text_orientation=&#8221;center&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p><span>Rys. Uk\u0142ad pomiarowy G\u0119sto\u015bciomierza Radiometrycznego WILPO CG 111, gdzie:<\/span><\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<ul>\n<li>1. G\u0142owica izotopowa<\/li>\n<li>2. G\u0142owica detekcyjna<\/li>\n<li>3. Zesp\u00f3\u0142 mocuj\u0105cy do ruroci\u0105gu transportowego<\/li>\n<li>4. Uk\u0142ad kontrolera<\/li>\n<\/ul>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Podstawowe dane techniczne<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.24.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td><strong>Materia\u0142 podlegaj\u0105cy pomiarowi:<\/strong><\/td>\n<td width=\"321\">zawiesiny, ciecze<\/td>\n<\/tr>\n<tr>\n<td><strong>Metoda pomiaru:<\/strong><\/td>\n<td width=\"321\">absorpcja promieniowania gamma<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0179r\u00f3d\u0142o promieniowania gamma:<\/strong><\/td>\n<td width=\"321\">Cs-137 (\u017ar\u00f3d\u0142o zamkni\u0119te, posta\u0107 specjalna)<\/td>\n<\/tr>\n<tr>\n<td><strong>Detektor promieniowania gamma:<\/strong><\/td>\n<td width=\"321\">sonda scyntylacyjna z kryszta\u0142em NaI(Tl)<\/td>\n<\/tr>\n<tr>\n<td><strong>Napi\u0119cie znamionowe zasilania U<sub>N<\/sub>:<\/strong><\/td>\n<td width=\"321\">230V, 50 Hz<\/td>\n<\/tr>\n<tr>\n<td><strong>Moc pobierana:<\/strong><\/td>\n<td width=\"321\">50VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>G\u0119sto\u015bciomierz radiometryczny WILPO CG 111 Przeznaczenie \u2013 zastosowanieIzotopowy G\u0119sto\u015bciomierz WILPO CG 111 przeznaczony jest do ci\u0105g\u0142ych pomiar\u00f3w g\u0119sto\u015bci cieczy lub zawiesin transportowanych w ruroci\u0105gach a szczeg\u00f3lnie w zawiesin popio\u0142u.BudowaG\u0119sto\u015bciomierz CG 111 jest urz\u0105dzeniem bezobs\u0142ugowym, zabudowywanym bezpo\u015brednio na ruroci\u0105gach transportuj\u0105cych zawiesiny. Uk\u0142ad pomiarowy sk\u0142ada si\u0119 z kontrolera, kt\u00f3ry mo\u017ce pracowa\u0107 samodzielnie lub wsp\u00f3\u0142pracowa\u0107 z zewn\u0119trzn\u0105 jednostka [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-209","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/comments?post=209"}],"version-history":[{"count":4,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/209\/revisions"}],"predecessor-version":[{"id":573,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/209\/revisions\/573"}],"wp:attachment":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/media?parent=209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}