{"id":184,"date":"2023-07-24T22:12:34","date_gmt":"2023-07-24T20:12:34","guid":{"rendered":"http:\/\/www.wilpo.pl\/?page_id=184"},"modified":"2024-01-23T13:37:56","modified_gmt":"2024-01-23T12:37:56","slug":"popiolomierz-radiometryczny-wilpo-c-512","status":"publish","type":"page","link":"https:\/\/www.wilpo.pl\/en\/radiometric-ash-meter-wilpo-c-512\/","title":{"rendered":"Radiometric ash meter WILPO C 512"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; module_class=&#8221;sekcja-produkt&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; use_background_color_gradient=&#8221;on&#8221; background_color_gradient_stops=&#8221;rgba(255,255,255,0.91) 0%|rgba(255,255,255,0.72) 100%&#8221; background_color_gradient_overlays_image=&#8221;on&#8221; background_image=&#8221;https:\/\/www.wilpo.pl\/wp-content\/uploads\/2023\/07\/Projekt-bez-nazwy-22.jpg&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h1>Popio\u0142omierz radiometryczny WILPO C 512<\/h1>\n<h2>Przeznaczenie \u2013 zastosowanie<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]Popio\u0142omierz radiometryczny WILPO C 512 przeznaczony jest do ci\u0105g\u0142ych pomiar\u00f3w zawarto\u015bci popio\u0142u w w\u0119glu kamiennym i brunatnym, dla praktycznie dowolnych wysoko\u015bci warstwy i granulacji w\u0119gla, wprost na przeno\u015bniku ta\u015bmowym o dowolnej szeroko\u015bci konstrukcji.<\/p>\n<p>Zastosowana w popio\u0142omierzu nowatorska, rozproszeniowo-absorpcyjna metoda pomiarowa, umo\u017cliwia prowadzenie pomiar\u00f3w r\u00f3wnie\u017c, co jest zupe\u0142n\u0105 nowo\u015bci\u0105, na ta\u015bmach transportowych z linkami stalowymi. Predysponuje to ten typ popio\u0142omierza do zastosowa\u0144 na d\u0142ugich, otwartych ci\u0105gach transportowych, zw\u0142aszcza w odkrywkowych kopalniach w\u0119gla.[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.wilpo.pl\/wp-content\/uploads\/2023\/07\/popiolomierz-radiometryczny-c512-1.jpg&#8221; title_text=&#8221;popiolomierz-radiometryczny-c512 (1)&#8221; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Budowa<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>Popio\u0142omierz WILPO C 512 zbudowany jest z dw\u00f3ch g\u0142\u00f3wnych zespo\u0142\u00f3w: stanowiska pomiarowego i stanowiska odczytowego. Stanowisko pomiarowe sk\u0142ada si\u0119 z zawieszenia, g\u0142owicy izotopowej z odpowiednio dobranym \u017ar\u00f3d\u0142em promieniowania gamma Am 241, odpowiednio usytuowanych g\u0142owic detekcyjnych oraz zespo\u0142u elektroniki.<\/p>\n<p>Gabaryty konstrukcji zawieszenia uzale\u017cnione s\u0105 od wymiar\u00f3w i rodzaju konstrukcji przeno\u015bnika. Podstawow\u0105 cz\u0119\u015bci\u0105 stanowiska odczytowego jest zesp\u00f3\u0142 komputera, ze specjalistycznym oprogramowaniem umo\u017cliwiaj\u0105cym realizacj\u0119 r\u00f3\u017cnych funkcji pomiarowych, wizualizacj\u0119 wynik\u00f3w (cyfrow\u0105 i graficzn\u0105), rejestracj\u0119 wszystkich wynik\u00f3w w specjalizowanej bazie danych oraz ich transmisj\u0119 do wskazanych punkt\u00f3w, np. dyspozytorni.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.wilpo.pl\/wp-content\/uploads\/2023\/07\/popiolomierz-radiometryczny-c512-budowa-800&#215;450-1.jpg&#8221; title_text=&#8221;popiolomierz-radiometryczny-c512-budowa-800&#215;450&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p><strong>Rys. Stanowisko pomiarowe popio\u0142omierza WILPO C 512, gdzie:<\/strong><\/p>\n<ul>\n<li>1 \u2013 g\u0142owica izotopowa GC9<\/li>\n<li>2 \u2013 g\u0142owica pomiarowa GC8 (rozproszenie)<\/li>\n<li>3 \u2013 g\u0142owica pomiarowa GC8 (absorpcja)<\/li>\n<li>4 \u2013 czujnik wysoko\u015bci warstwy CW1<\/li>\n<li>5 \u2013 zawieszenie ZC12<\/li>\n<li>6 \u2013 zesp\u00f3\u0142 sterownika ZS1<\/li>\n<\/ul>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Podstawowe dane techniczne<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.24.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td width=\"270\"><strong>Rodzaj w\u0119gla:<\/strong><\/td>\n<td width=\"321\">w\u0119giel kamienny i brunatny<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Granulacja w\u0119gla:<\/strong><\/td>\n<td width=\"321\">0 \u2013 300 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Wysoko\u015b\u0107 warstwy w\u0119gla:<\/strong><\/td>\n<td width=\"321\">min. 100 mm (start pomiaru) max. 500 mm (chwilowo do 750 mm )<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Ta\u015bma przeno\u015bnika:<\/strong><\/td>\n<td width=\"321\">zwyk\u0142a, przek\u0142adkowa lub z linkami stalowymi<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>\u0179r\u00f3d\u0142o promieniowania gamma: <\/strong><\/td>\n<td width=\"321\">Am 241 (\u017ar\u00f3d\u0142o zamkni\u0119te, posta\u0107 specjalna, aktywno\u015b\u0107 dobierana z przedzia\u0142u 3,7 do 37 GBq)<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Dok\u0142adno\u015b\u0107 pomiaru (\u03c3) zaw. popio\u0142u:<\/strong><br \/><strong> w zakresie 0 \u2013 15% <span style=\"font-family: Calibri;\">A<sup>r<\/sup><\/span><\/strong><br \/><strong> w zakresie 15 \u2013 30% <span style=\"font-family: Calibri;\">A<sup>r<\/sup><\/span><\/strong><br \/><strong> w zakresie &gt;30% <span style=\"font-family: Calibri;\">A<sup>r<\/sup><\/span><\/strong><\/td>\n<td width=\"321\">1,5%<br \/>2,0%<br \/>2,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Napi\u0119cie znamionowe zasilania UN:<\/strong><\/td>\n<td width=\"321\">230V, 50 Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Moc pobierana:<\/strong><\/td>\n<td width=\"321\">300 VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Popio\u0142omierz radiometryczny WILPO C 512 Przeznaczenie \u2013 zastosowaniePopio\u0142omierz radiometryczny WILPO C 512 przeznaczony jest do ci\u0105g\u0142ych pomiar\u00f3w zawarto\u015bci popio\u0142u w w\u0119glu kamiennym i brunatnym, dla praktycznie dowolnych wysoko\u015bci warstwy i granulacji w\u0119gla, wprost na przeno\u015bniku ta\u015bmowym o dowolnej szeroko\u015bci konstrukcji. Zastosowana w popio\u0142omierzu nowatorska, rozproszeniowo-absorpcyjna metoda pomiarowa, umo\u017cliwia prowadzenie pomiar\u00f3w r\u00f3wnie\u017c, co jest zupe\u0142n\u0105 nowo\u015bci\u0105, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-184","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/184","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/comments?post=184"}],"version-history":[{"count":4,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/184\/revisions"}],"predecessor-version":[{"id":569,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/184\/revisions\/569"}],"wp:attachment":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/media?parent=184"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}