{"id":184,"date":"2023-07-24T22:12:34","date_gmt":"2023-07-24T20:12:34","guid":{"rendered":"http:\/\/www.wilpo.pl\/?page_id=184"},"modified":"2024-01-23T13:37:56","modified_gmt":"2024-01-23T12:37:56","slug":"popiolomierz-radiometryczny-wilpo-c-512","status":"publish","type":"page","link":"https:\/\/www.wilpo.pl\/en\/radiometric-ash-meter-wilpo-c-512\/","title":{"rendered":"Radiometric ash meter WILPO C 512"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; module_class=&#8221;sekcja-produkt&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; use_background_color_gradient=&#8221;on&#8221; background_color_gradient_stops=&#8221;rgba(255,255,255,0.91) 0%|rgba(255,255,255,0.72) 100%&#8221; background_color_gradient_overlays_image=&#8221;on&#8221; background_image=&#8221;https:\/\/www.wilpo.pl\/wp-content\/uploads\/2023\/07\/Projekt-bez-nazwy-22.jpg&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h1>Radiometric ash meter WILPO C 512<\/h1>\n<h2>Applied measurement methods<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]Popio\u0142omierz radiometryczny WILPO C 512 przeznaczony jest do ci\u0105g\u0142ych pomiar\u00f3w zawarto\u015bci popio\u0142u w w\u0119glu kamiennym i brunatnym, dla praktycznie dowolnych wysoko\u015bci warstwy i granulacji w\u0119gla, wprost na przeno\u015bniku ta\u015bmowym o dowolnej szeroko\u015bci konstrukcji.<\/p>\n<p>Zastosowana w popio\u0142omierzu nowatorska, rozproszeniowo-absorpcyjna metoda pomiarowa, umo\u017cliwia prowadzenie pomiar\u00f3w r\u00f3wnie\u017c, co jest zupe\u0142n\u0105 nowo\u015bci\u0105, na ta\u015bmach transportowych z linkami stalowymi. Predysponuje to ten typ popio\u0142omierza do zastosowa\u0144 na d\u0142ugich, otwartych ci\u0105gach transportowych, zw\u0142aszcza w odkrywkowych kopalniach w\u0119gla.[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.wilpo.pl\/wp-content\/uploads\/2023\/07\/popiolomierz-radiometryczny-c512-1.jpg&#8221; title_text=&#8221;popiolomierz-radiometryczny-c512 (1)&#8221; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Construction<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>The WILPO C 512 Ash Meter comprises two main units: measuring unit and readout unit. The measuring unit consists of a supporting structure, radiation head with dedicated Am 241 gamma radiation source, appropriately positioned detection heads and electronic system. The supporting structure dimensions depend on the size and type of the belt conveyor.<\/p>\n<p>The supporting structure dimensions depend on the size and type of the belt conveyor. The basic component of the readout unit is a computer with dedicated software for carrying out various measuring functions, display of results (in numerical and graphical form), data recording and transmission to indicated recipients, e.g. to a control room.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.wilpo.pl\/wp-content\/uploads\/2023\/07\/popiolomierz-radiometryczny-c512-budowa-800&#215;450-1.jpg&#8221; title_text=&#8221;popiolomierz-radiometryczny-c512-budowa-800&#215;450&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p><strong>Measurement unit of WILPO C 512 Ash Meter, where:<\/strong><\/p>\n<ul>\n<li>1 \u2013 isotope head<\/li>\n<li>2 \u2013 measurement head (scatter)<\/li>\n<li>3 \u2013 measurement head (absorption)<\/li>\n<li>4 \u2013 layer thickness detector<\/li>\n<li>5 \u2013 support<\/li>\n<li>6 \u2013 controller unit<\/li>\n<\/ul>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; header_2_text_color=&#8221;#7fda41&#8243; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Basic technical data<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.24.0&#8243; _module_preset=&#8221;default&#8221; text_text_color=&#8221;#000000&#8243; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td width=\"270\"><strong>Coal type:<\/strong><\/td>\n<td width=\"321\">hard coal and lignite,<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Coal grain size:<\/strong><\/td>\n<td width=\"321\">0 \u2013 300 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Coal layer thickness:<\/strong><\/td>\n<td width=\"321\">min. 100 mm (measurement start) max. 500 mm (temporarily up to 750 mm)<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Conveyor belt:<\/strong><\/td>\n<td width=\"321\">plain, sandwich or with steel cables<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Gamma radiation source: <\/strong><\/td>\n<td width=\"321\">Am 241 (closed source, special form, activity selected from 3.7 to 37 GBq)<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Ash content determination accuracy (\u03c3):<\/strong><br \/><strong> in the range of 0 \u2013 15% <span style=\"font-family: Calibri;\">A<sup>r<\/sup><\/span><\/strong><br \/><strong> in the range of 15 \u2013 30% <span style=\"font-family: Calibri;\">A<sup>r<\/sup><\/span><\/strong><br \/><strong> in the range &gt;30% <span style=\"font-family: Calibri;\">A<sup>r<\/sup><\/span><\/strong><\/td>\n<td width=\"321\">1,5%<br \/>2,0%<br \/>2,5%<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Rated supply voltage UN:<\/strong><\/td>\n<td width=\"321\">230V, 50 Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"270\"><strong>Power consumption:<\/strong><\/td>\n<td width=\"321\">300 VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>","protected":false},"excerpt":{"rendered":"<p>Popio\u0142omierz radiometryczny WILPO C 512 Przeznaczenie \u2013 zastosowaniePopio\u0142omierz radiometryczny WILPO C 512 przeznaczony jest do ci\u0105g\u0142ych pomiar\u00f3w zawarto\u015bci popio\u0142u w w\u0119glu kamiennym i brunatnym, dla praktycznie dowolnych wysoko\u015bci warstwy i granulacji w\u0119gla, wprost na przeno\u015bniku ta\u015bmowym o dowolnej szeroko\u015bci konstrukcji. Zastosowana w popio\u0142omierzu nowatorska, rozproszeniowo-absorpcyjna metoda pomiarowa, umo\u017cliwia prowadzenie pomiar\u00f3w r\u00f3wnie\u017c, co jest zupe\u0142n\u0105 nowo\u015bci\u0105, [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"_links":{"self":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/184"}],"collection":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/comments?post=184"}],"version-history":[{"count":4,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/184\/revisions"}],"predecessor-version":[{"id":569,"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/pages\/184\/revisions\/569"}],"wp:attachment":[{"href":"https:\/\/www.wilpo.pl\/en\/wp-json\/wp\/v2\/media?parent=184"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}